Sas and sata hard drive led combinations, Pci riser cage led – HP ProLiant DL385 G2 Server User Manual

Page 18

Advertising
background image

Component identification 18

SAS and SATA hard drive LED combinations

Online/activity
LED (green)

Fault/UID LED
(amber/blue)

Interpretation

On, off, or

flashing

Alternating amber and

blue

The drive has failed, or a predictive failure alert has been

received for this drive; it also has been selected by a
management application.

On, off, or

flashing

Steadily blue

The drive is operating normally, and it has been selected by a

management application.

On Amber,

flashing

regularly (1 Hz)

A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.

On

Off

The drive is online, but it is not active currently.

Flashing regularly
(1 Hz)

Amber, flashing
regularly (1 Hz)

Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is part of an array that is undergoing capacity

expansion or stripe migration, but a predictive failure alert has
been received for this drive. To minimize the risk of data loss,

do not replace the drive until the expansion or migration is

complete.

Flashing regularly
(1 Hz)

Off

Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is rebuilding, or it is part of an array that is

undergoing capacity expansion or stripe migration.

Flashing
irregularly

Amber, flashing
regularly (1 Hz)

The drive is active, but a predictive failure alert has been
received for this drive. Replace the drive as soon as possible.

Flashing
irregularly

Off

The drive is active, and it is operating normally.

Off

Steadily amber

A critical fault condition has been identified for this drive, and
the controller has placed it offline. Replace the drive as soon as

possible.

Off Amber,

flashing

regularly (1 Hz)

A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.

Off

Off

The drive is offline, a spare, or not configured as part of an

array.

PCI riser cage LED

CAUTION:

To prevent damage to the server or expansion boards, power down the server and

remove all AC power cords before removing or installing the PCI riser cage.

Advertising