Fru codes – HP Surestore Disk Array 12h and FC60 User Manual

Page 322

Advertising
background image

322 Status Conditions and Sense Code Information

FRU Codes

The FRU codes indicate which disk array component is responsible for the log entry. Log
entries that do not involve disk modules typically require you to interpret the FRU Code
and the FRU Code Qualifier values to determine which component is identified.

To simplify reporting events, components within the disk array have been placed in FRU
groups. The FRU Code indicates which FRU group the component is a member of. The
FRU Code Qualifier further identifies the specific component within the group, and the
component’s status.

Table 43

FRU Code Groups

FRU Code Value

Group Description

0x01

Host Channel Group - comprises the host SCSI bus, its SCSI interface
chip, and all initiators and other targets connected to the bus.

0x02

Controller Drive Interface Group - comprises the SCSI interface chips on
the controller which connect to the drive buses.

0x03

Controller Buffer Group - comprises the controller logic used to
implement the on-board data buffer.

0x04

Controller Array ASIC Group - comprises the ASICs on the controller
associated with the array functions.

0x05

Controller Other Group - comprises all controller related hardware not
associated with another group.

0x06

Controller Enclosure Group - comprises components that are monitored
by the array controller, such as power supplies, fans, thermal sensors,
and AC power monitors. See

"Controller Enclosure Group FRU Code

Qualifier" on page 324

for information on identifying component and

status.

0x07

Subsystem Configuration Group - comprises subsystem components
that are configurable by the user, on which the array controller will display
information (such as faults).

Advertising