Document # 100452 RevL

20

Printed in USA © 2013

2.1

a

b

c

d

e

f

g

Return to step 1

Step 2.1 continue here

Call 1 888-Brewer1 for technical

assistance.

Front cabinet switch (one of 6) is

stuck on. (closed) Unplug table

power. Isolate faulty switch or wire

using a continuity tester. Replace

or repair.

Is green light on at back side of

control box?

No

Yes

Is the table stuck in the up

position?

No

Still bad

Fixed

No heater or No

Table does not go down. Control

box relay clicks in down direction.

When front bottom switch plate is

lifted there is no relay click.

No

Yes

Call 1 888-Brewer1 for technical

assistance.

Return to step 1

Return to step 1

Check for loose wire connections

at terminal block.

Return to step 1

Return to step 1

If table has a heater, is the switch

illuminated when turned on?

Yes

Still bad

Fixed

Press foot control pedal. Does

relay in control box click?

Yes

Replace 2 control box fuses.

Still bad

Is on/off switch on back of cabinet

turned on?

Yes

No

Check for loose plug in wall outlet

or back of table. Check for power

at outlet.

Yes

No

Fixed

Replace control box.

Still bad

Fixed

Ok

Turn on switch, then return to step 1

Fixed

6000 SERIES TABLE TROUBLESHOOTING CHART (continued)

Advertising