Repairing a mirror conflict – Asus Motherboard P5VD2-MX User Manual

Page 106

Advertising
background image

3-8

Chapter 3: Software support

Repairing a Mirror conflict

A Mirror conflict occurs when one or both disks in a RAID 1 (Mirror)

configuration are unplugged from the system, then plugged in again. Since

both disks contain exactly the same data, the system will be unable to

determine which of the two is the source drive. This option allows you to

set the source drive and rebuild the Mirror drive according to the contents

of the source drive.

To repair a Mirror conflict:
1. In the main JMB363 RAID BIOS menu, highlight Repair Mirror Conflict

using the up/down arrow key then press <Enter>.

2. Use the space bar to select the HDD that you want to set as source

drive.

The selected HDD shows a sign before it.

3. Using the <TAB>, move to the RAID Disk Drive List menu and highlight

the RAID set that you want to rebuild. Press <Del> to begin rebuilding

the Mirror configuration.

[Main Menu]
Create RAID Disk Drive

Delete RAID Disk Drive

Revert HDD to Non-RAID

Repair Mirror Conflict

Save and Exit Setup

Exit Without Saving

JMicron Technology Corp. PCI-to-SATA II/IDE RAID Controller BIOS v0.97

[Hard Disk Drive List]

Model Name

Capacity

Type/Status

HDD0: HDS722516VLSA80 164 GB

RAID Inside

HDD1: HDS722516DLA380 164 GB

RAID Inside

[RAID Disk Drive List]

Model Name

RAID Level

Capacity

Status

Members(HDDx)

RDD0: JRAID

1-Mirror

XXX GB

Rebuild

01

[Main Menu]
Create RAID Disk Drive

Delete RAID Disk Drive

Revert HDD to Non-RAID

Repair Mirror Conflict
Save and Exit Setup

Exit Without Saving

Rebuilding... 01%, please wait...