Stagehand User’s Manual, page 14

How to reprogram the receiver

Add ID code and channel:

(If you are reprogramming for the purpose of avoiding conflicts, skip to the next section

since you will first want to erase all ID codes and channels)

With the USB receiver plugged into the powered on computer, take a narrow

instrument, such as the uncurled end of a paperclip, and push and hold the reprogram

button on the USB receiver until the LED indicator on the receiver (not the LED

illumination light on the remote control) flashes two times.

Then quickly release the button within 1.5 seconds.

Next, push the up button or down button on the remote control several times so that

the USB receiver can receive signals from the remote control.

If the LED on the receiver flashes when you send signals, this indicates that the

receiver has learned the new ID code and channel. It will still respond to its original

and any previously added ID codes and channels as well (as long as you have not

erased them per the procedure described further below).

Note: the receiver will abandon the process of adding a new ID code and channel if you

wait more than 15 seconds to send a signal from the remote control or if you unplug

the receiver. Also, since the receiver will not add the ID code and channel of a remote

control it already is actively programmed to recognize, if you send a signal from your

currently recognized remote control(s), the LED on the receiver will not accept it and

will not flash during this 15 second reprogramming period.

You can repeat this procedure up to seven times for a total of eight learned ID codes

and channels that will operate simultaneously. If you try to add more than seven

additional ID codes and channels, the LED will flash but no ID code and channel will

be added.