Mounting the Interface Cable Adapter Module
Page 5
5. Attach cables to the ICAM as shown below.
C
ONNECTING
THE
C
ABLES
✦
If connecting to the AOM from the ICAM, connect one end of the
AOM cable to connector S6.
✦
Attach one end of the standard 8-conductor cable which runs from
the ICAM to the console to connector S7 on the ICAM.
✦
If running shielded 8-conductor cable from the SIM to the ICAM,
strip 4” (10 cm) of cable jacket and shield (the grey outer covering
and foil-like inner covering) and strip 5/16” (8 mm) of insulation
(the colored covering) from each wire. Feed the wires through the
ferrite bead and insert into terminal block connector C2 according to
the wire colors printed on the circuit board. (To place wires into a
terminal, use a small screwdriver to push down on the lever next to
the terminal, insert the exposed wire into the opening created, and
release the lever. When you release the lever, the wire(s) will be held
in place.) Connect the bare drain wire to the Shield terminal (JP2).
Cut off any excess drain wire.
✦
If running standard 8-conductor cable from the SIM to the ICAM,
you may connect to either modular connector C2 or terminal block
connector C2 (continued on next page).