Specifications

52

900-0112-01-00 Rev B

Table 22

48-Volt Inverter Settings (MATE3)

Field Item Default

Minimum

Maximum

Sensitivity (see page 14 for increments)

6 0 50

Pulse Length

8 4 20

Search

Pulse Spacing

60 AC cycles

4 AC cycles

120 AC cycles

Input Type

Grid

Grid or Gen

Input Support

Y

Y or N

Grid Input AC Limit

25 Aac

2.5 Aac

30 Aac

Gen Input AC Limit

25 Aac

2.5 Aac

30 Aac

AC Input and
Current Limit

Charger AC Limit

5.5 Aac

0 Aac

6 Aac

AC1/Grid Lower Limit

208 Vac

140 Vac

220 Vac

AC1/Grid Upper Limit

252 Vac

250 Vac

280 Vac

Grid AC Input
Voltage Limits

AC1/Grid Transfer Delay

6 AC cycles

0 AC cycles

240 AC cycles

LowerVoltage Limit

208 Vac

140 Vac

220 Vac

Upper Voltage Limit

252 Vac

250 Vac

280 Vac

Transfer Delay

60 AC cycles

0 AC cycles

240 AC cycles

Gen AC Input
Voltage Limits

Connect Delay

0.5 minutes

0.2 minutes

15 minutes

AC Output

AC Output

230 Vac

210 Vac

250 Vac

Cut-Out Voltage

42 Vdc

36 Vdc

48 Vdc

Low Battery

Cut-In Voltage

50 Vdc

40 Vdc

56 Vdc

Absorb Voltage

57.6 Vdc

52 Vdc

64 Vdc

(Absorb) Time

1.0 hours

0.0 hours

24.0 hours

Float Voltage

54.4 Vdc

48 Vdc

60 Vdc

(Float) Time

1.0 hours

0.0 hours

24.0 hours

Battery Charger

Re-Float Voltage

50 Vdc

48 Vdc

26 Vdc

Equalize Voltage

58.4 Vdc

56 Vdc

68 Vdc

Battery Equalize

(Equalize) Time

1.0 hours

0.0 hours

24.0 hours

Aux Mode

Cool Fan

Remote, Load Shed, Gen Alert, Fault, Vent Fan,

Cool Fan, Divert DC, Divert AC, or AC Drop

(Load Shed) Enable Voltage

44 Vdc

40 Vdc

56 Vdc

(Gen Alert) ON Voltage

44 Vdc

40 Vdc

56 Vdc

(Gen Alert ON) Delay

4 minutes

0 minutes

240 minutes

(Gen Alert) OFF Voltage

56 Vdc

48 Vdc

72 Vdc

(Gen Alert OFF) Delay

9 minutes

0 minutes

240 minutes

(Vent Fan) Enable Voltage

52 Vdc

40 Vdc

64 Vdc

(Vent Fan) Off Period

5 minutes

0 minutes

30 minutes

(Divert DC or AC) Enable Voltage

58.4 Vdc

48 Vdc

64 Vdc

Auxiliary
Output

(Divert DC or AC) Off Delay

30 seconds

0 seconds

240 seconds

Inverter
Stacking

Stack Mode

Master

Master, OB Slave L1, 3p Classic B , 3p Classic C

Master Adjust Only

0 0 7

Power Save

Slave Adjust Only

1 1 15

Grid Tie Enable

Y

Y or N

Sell Voltage

47.2 Vdc

40 Vdc

60 Vdc

Grid-Tie Sell

Grid Tie Window

IEEE

IEEE or user

Input Voltage

11

-1 -3 1

Output Voltage

11

-1 -3 1

Calibrate

Battery Voltage

12

0.0 -0.8 0.8


11

These values represent an adjustable setting with a total range of 4 Vac. The default value of -1 means the calibration will subtract 1 volt from the measured

value. The range of settings allow up to 1 volt to be added to the measured value, or up to 3 volts to be subtracted from it. The result is also displayed.

12

These values represent an adjustable setting with a range of ± 0.8 Vdc from the measured value. The range of settings allow up to 0.8 volts to be either added

or subtracted from the measured value (in increments of 0.4 Vdc). The result is also displayed.