Sandvik Coromant Silent tools - application guide User Manual

Page 63

Advertising
background image

61

3. Turning

Two lines on the bar indicate minimum and
maximum overhang. Make sure that the
overhang is within that range. Outside this
range, there is no guarantee for the damp-
ening function.

Modification of standard bars

Bar diameter

L, min length after cut off

BD

Short design
4–7 × BD

Long design
7–10 × BD

mm

mm

mm

16

100

155

20

125

200

25

155

255

32

190

320

40

240

410

50

305

520

60

380

630

80

630

630

100

770

770

We recommend a min. clamping length of 4 × BD

Bar diameter

L, min length after cut off

BD

Short design
4–7 × BD

Long design
7–10 × BD

inch

inch

inch

0.625

4

7

0.750

5

8

1.000

7

11

1.250

8

13

1.500

10

17

1.750

10.4

18

2.000

12

21

2.500

15

25

3

20

20

4

30.3

30.3

We recommend a minimum clamping length of 4 × BD

Advertising