INSTALLATION

Type of Error

Indication

Release of Error

Undervoltage

LED fl ashing sequence, with 1 fl ash per period.

Voltage of intermediate circuit is less than 250V

Overvoltage

LED fl ashing sequence, with 2 fl ashes per period. Voltage of intermediate circuit exceeds 445V

Excess
Temperature

LED fl ashing sequence, with 3 fl ashes per period. Temperature sensor in the power unit is more than 93°C

Overcurrent

LED fl ashing sequence, with 4 fl ashes per period.

Blocked motor, detected by current peak monitoring from
900 rpm rotating fi eld

Overcurrent

LED fl ashing sequence, with 5 fl ashes per period. Intermediate circuit current exceeds 4.0A

Short-circuit

LED fl ashing sequence, with 6 fl ashes per period.

Release of interrupt at intermediate circuit current larger
than 53A

Power on

LED fl ashing sequence, with 7 fl ashes per period.

Effective mains voltage does not correspond to jumper
setting 115V/230V

Watchdog

LED fl ashing sequence, with 8 fl ashes per period. Watchdog of the microcontroller released, program crash