Ethernet settings, Serial port settings, Ethernet settings serial port settings – Vaisala vNet PoE Network Interface User Manual

Page 19

Advertising
background image

vNet User’s Guide

13

The factory default NetBIOS name is VERITEQXXXXXXXX
(X denotes the 8-digit serial number of the vNet device).

To change the NetBIOS name:

1

From the vNet Configuration and Management interface,
choose

Configuration | Network | IP Settings.

2

In the NetBIOS name field you can enter up to 15 characters
(using letters, numbers, and underscores). To avoid a
network conflict, do not assign the same name to another
vNet Device.

3

Click

Apply

. When prompted, click the

here

link to restart the

vNet Device.

Ethernet Settings

Depending on the network hub or switch the vNet Device is
connected to, you may want to change the Ethernet mode from
the default setting, half-duplex, to full-duplex.

To change the Ethernet settings for your vNet Device:

1

From the vNet Configuration and Management interface,
choose

Configuration | Network | Ethernet Settings

.

2

Choose the desired Duplex Mode (Half or Full).

3

Click

Apply

. When prompted, click the

here

link to restart the

vNet Device.

Note:

The speed setting is fixed at 10Mbit and cannot be
changed.

Serial Port Settings

The vNet Device communicates with the Vaisala Veriteq Logger
through a serial port; however, communication between the PC
and the vNet is through TCP ports.
Because TCP port numbers can change, use the Serial Port
Settings screen to configure the vNet Device to continue to use