Wiring and Installation

8

IR Sensors and Receivers

!

To receive 455 kHz, position the jumper (both jumpers on the receivers) on the left two

pins, pins 1 and 2, away from the edge of the circuit boards, to receive 455 kHz. (This is

the default setting.)

!

To receive 38 kHz, position the jumper (both jumpers on the receivers) on the right two

pins, pins 2 and 3, near the edge of the circuit boards, to receive 38 kHz.

2.

Go on to the next procedure:

!

If you are installing a receiver, go on to Configuring the Receivers.

!

If you are installing an IR sensor, refer to Sensor IR validation level in Configuring the

Receivers before going on to Installation.

Configuring the Receivers

To configure the receivers, set the AXlink device number and the IR validation level.

Setting the AXlink Device Number

Perform the following steps to set the receiver's AXlink device number:

1.

Locate the eight-position Device DIP switch (FIG. 11).

2.

Set the DIP switch according to the DIP switch values shown in FIG. 12.

The device number is set by the total value of DIP switch positions that are ON (down). The

Axcess software program in your system typically uses device numbers 128 through 255 for

the panels.

FIG. 10 Receive frequency jumper settings

FIG. 11 IR receiver AXlink device DIP switches, IR validation jumper pins, AXlink connector, and receive
frequency jumper pin locations

Switch 1 2 3 4

5

6

7

8

Value

1 2 4 8 16 32 64 128

IR SNSR
38/455
kHz

Setting for 455 kHz

IR SNSR
38/455
kHz

Setting for 38 kHz (default)

IR validation jumper pins

AXlink Device DIP switch

AXlink connector