Wiring and Installation

11

IR Sensors and Receivers

the receiver or sensor and the Central Controller. The maximum wiring lengths are based on a

minimum of 13.5 volts available at the Central Controller's power supply.

If you install the IR sensor or receiver farther away from the Central Controller than recommended

in the Wiring Specifications table, connect an external 12 VDC power supply, as shown in the

wiring diagrams in this section.

Connecting the Wiring

The following paragraphs describe wiring connections using AXlink for data and power, using

AXlink plus an external 12 VDC power supply, and wiring the IRX-DM+ or IRX-SM+ to the AMX

IR receiver.

Wiring the AXD-IR+ or the AXR-IRSM+ to AXlink

Install the AXlink data/power bus wiring as shown in FIG. 15.

Using the AXlink four-pin connector with an external 12 VDC power supply

Connect the Central Controller's AXlink connector to the AXlink connector on the AXD-IR+ or the

AXR-IRSM+ as shown in FIG. 16.

Wiring Specifications

Maximum Wiring Length

Wire Size

IR Sensors

IR Receivers

18 AWG

4,696 feet (1431.34 m) 3,354 feet (1022.30 m)

20 AWG

2,970 feet (905.26 m)

2,121 feet (646.48 m)

22 AWG

1,851 feet (564.18 m)

1,314 feet (400.511 m)

24 AWG

1,167 feet (355.70 m)

833 feet (253.90 m)

FIG. 15 AXlink wiring

FIG. 16 AXlink wiring diagram using an external 12 VDC power supply

1

3

2

4

GND (-)

AXP

AXM

PWR (+)

(-) GND

AXP

AXM

(+) PWR

1

3

2

4

AXlink connector on

the AXD-IR+ or the

AXR-IRSM+

Control system

12 VDC power supply

Control system

1

3

2

4

GND (-)

AXP

AXM

PWR (+)

1

3

2

4

PWR (+)
GND (-)

(-) GND

AXP

AXM

(+) PWR

AXlink connector on the AXD-IR+
or the AXR-IRSM+