7. […S] – SAVE

This command will save the configuration
command being sent in memory. When
sending the command [VLBA12C4S], after
reset or power up, the bass level on C4 will be
12 out of 16.

8. […F] – FEEDBACK

After processing a command, an OK or ER will
be returned as feedback if "F" is included at the
end of some command strings.

9. [ + ] and [ - ]

These commands allow a selected property to
be adjusted from keyboard commands or
programmed front panel buttons.

Command Format: [ + ], [ - ]

[+] = Increment level by one step

[-]

= Decrement level by one step

Example:

Select the Output Volume command for the
card in slot #4. The current Output Volume level
is 10, but it is not the optimal value. After
sending the following commands, an optimum
volume level of 15 is obtained:

1.

[SELOC4]
The current volume level is 10.

2.

[ ] [ ] [ ]
The level is now 7 and is too low.

3.

[+][+][+][+][+][+][+][+]
The level is now 15 and no further

adjustments are required.

10. [SELIm]

This command sets the path to adjust the
INPUT volume level. The input volume range is
00 to 16 and is adjustable using the [+] and [-]
commands.

Command Format: [SELImCnUi]

m

= Input (m = # from 1 to 3)

Cn = Card ID (n = slot # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

Example:

An MT109-102 is in slot #4. Adjust the volume
on Input 2 by sending the command [SELI2C4]
and then using the [+] and [-] commands.

11. [SELO]

This command sets the path to adjust the
OUTPUT volume level. The output volume
range is 00 to 16 and is adjustable using the [+]
and [-] commands or the Volume Ramping
commands.

Command Format: [SELOCnUi]

Cn = Card ID (n = slot # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

Example 1:

An MT109-102 is in slot #4. Adjust the output
volume by sending the command [SELOC4]
and then using the [+] and [-] commands.

Example 2:

The output volume may also be adjusted using
key ramping commands. See the VOLUME
RAMPING FEATURE section of this manual for
details on using this feature.

12. [SELB]

This command sets the path to adjust the bass
level. The BASS level range is 00 to 16 and is
adjustable using the [+] and [-] commands.

Command Format: [SELBCnUi]

Cn = Card ID (n = slot # from 1 to max slots)

Ui

= Unit ID (i = # from 0 to 9)

Advertising