Application examples, Dual solenoid control, Pv200 – High Country Tek ProValve 200 Series User Manual

Page 19: Closed loop proportional valve controller

Advertising
background image

021-PV200 Rev A

PV200 Uses Manual

19

Copyright © High Country Tek, Inc.

– 2013

PV200

Closed Loop Proportional Valve Controller

Application Examples

Dual Solenoid Control

The PV200 can drive two solenoids for closed-loop position control.

Set the dither and output settings according to the valve specifications.

FUSE

+V Power Input
12 - 30VDC

PWR 1

PV200

Electronic
Valve
Controller

PWR GND 2

Proportional PWM (Sourcing)

Dig I/P GND 13

Coil B 11

Proportional PWM (Sourcing)

Frame GND 7

TGTV 3

Coil A 9

POSV 4

TGTI 5

POSI 6

Target position (0-5V, or 0-10V)

Coil A 10

Coil B 12

ENB 14

FOR 15

ROR 16

Actual position (0-5V, or 0-10V)

m

A

I/

P

External
Voltage

Target position (4-20mA)

Sig GND 8

+V = enabled

Forward override

Reverse override

Actual position (4-mA)

External
Voltage

V

D

C

I/

P

Advertising