Physical description, User interface, Pv200 – High Country Tek ProValve 200 Series User Manual

Page 6: Closed loop proportional valve controller

Advertising
background image

021-PV200 Rev A

PV200 Uses Manual

6

Copyright © High Country Tek, Inc.

– 2013

PV200

Closed Loop Proportional Valve Controller

Physical Description

The boxed numbers 1 to 16 represent the terminal positions. A label on the side
of the module provides a list of terminal functions.

The “POWER” LED is green when the applied voltage is within the operating
range.

The “OUTPUT A” and “OUTPUT B” LEDs are yellow and the brightness will vary
with the output current.

In the case of a fault the “FAULT” LED will display solid red. See Fault Status for
details.

The PV200 communicates with the Graphical User Interface through RJ-11 to
DB9 convertor. It must be powered when configuring the settings.

User Interface

The PV200 has a number of internal settings.

Users can open the Graphical User Interface to view, make changes and save the settings in a data file which can
be uploaded to any PV200 controller.

The Hand Held Interface can also be used to view and make changes, but this device does not have the capability
to save the settings in a data file. The programmer, cable and adapter are self-contained which makes the HHI a
viable alternative for field work.

The following diagram shows the RJ-11 to DB9 converter pinout:

Advertising