Ab c m – Nilfisk-ALTO DELTABOOSTER 7309021 User Manual

Page 23

Advertising
background image

23

50 m

40 m

70 m

a

b

c

M

1.7.5 Examples

The following examples have been worked out on the basis of stainless steel pipes and a 160
bar system, and the dimension requirements are

max.15 bar pressure drop from the machine

to the outlet points.

Example 1

Two different conditions may be used when
dimensioning the pipe system:

A. Based upon a fixed type of spray lance (capacity l/min)
B. Based upon max. capacity, i.e. all spray lances may be used anywhere

A:
If standard lances (17 l/min) are selected for outlet points

a, b and c the maximum load on line

b-c = 17 l/min.

PRESSURE

According to the diagram the use of a 50 m ∅15 mm

DROP

pipe will result in a pressure drop of:

2.3 bar

In the diagram you follow the 50 m division vertically
upwards to the curve symbolizing 17 l/min through an

∅15 mm pipe. From here proceed horizontally and a
pressure drop of 2.3 bar is had.

Maximum load on pipe line a-b = 35 l/min.
Use of 40 m Ø15 mm pipe will result in a pressure drop of:

7.4 bar

Maximum load on pipe line M-a = 51 l/min.
Use of 70 m Ø22 mm pipe will result in a pressure drop of:

3.3 bar

Total pressure drop

13.0 bar

The aggregate pressure drop on the three lines is less than 15 bar and the dimension requirements have therefore
been met.