Nilfisk-ALTO DELTABOOSTER 7309021 User Manual

Page 24

Advertising
background image

24

20

20

c

2

c

1

c

20

20

b

2

b

1

b

20

20

a

2

a

1

a

30 m

30 m

10 m

10 m

80 m

60 m

M

B:
If, on the other hand, a green spray lance is selected = 33 l/min + a standard spray lance = 17
l/min the maximum load on the line

b-c = 33 l/min.

PRESSURE

DROP

Use of 50 m ∅15 mm pipe will result in a pressure drop of:

9.3 bar

Maximum load on line

a-b = 50 l/min.

Use of 40 m ∅22 mm pipe will result in a pressure drop of:

2.0 bar

Maximum load on line

M-a = 50 l/min.

Use of 70 m ∅22 mm pipe will result in a pressure drop of:

3.2 bar


Total pressure drop

14.5 bar


The aggregate pressure drop on the three lines is less than

15 bar and the dimension require-

ments have therefore been met.

Example 2

Branched system

Selection of spray lance: 2 green spray lances each of 33 l/min

2 blue spray lances each of 17 l/min


PRESSURE

Maximum load in each branch is 33 l/min

DROP

Use of∅15 mm pipe on e.g. the

a-a2 line

(20m) will result in a pressure drop of:

4.0 bar


Maximum load on line

b-c = 66 l/min

Use of 30 m ∅22 mm pipe will result in a pressure drop of:

2.5 bar


Maximum load on line

a-b + M-a = 101 l/min

Use of 40 m ∅22 mm pipe will result in a pressure drop of:

7.5 bar


Total pressure drop

14.0 bar

The aggregate pressure drop on the three lines is less than

15 bar and the dimension require-

ments have therefore been met.

Advertising