Nilfisk-ALTO DELTABOOSTER 7309021 User Manual

Page 7

Advertising
background image

7

Water tank

The water tank of the

DELTABOOSTER has been constructed in accordance with BS 6281

part 1 (type A air gap). As standard the water tank is mounted for water connection in the

left

side (seen from in front) but the water tank is also available with prepared water connection in
the

right side.

The water tank of the

DELTABOOSTER incorporates the following:

- two solenoid valves for water inlet, cold and hot water respectively

- various control valves

- temperature sensor and level switches in the float tank

- overflow

- connection of up to 6 pumps

- filters in in-lets

C3K pumps

The C3K pumps are designed for the very demanding environments in which they are used. Their
durability has been achieved by the use of ceramic pistons *

)

and valves of stainless steel.

Each of the pumps are connected by individual non-return valves to a central manifold. Thus it
is ensured that a defective pump will not cause a malfunction or an unintentional by-pass situ-
ation.

*

)

The

C in the pump designation C3K stands for "Ceramic".

Advertising