Nilfisk-ALTO DELTABOOSTER 7309021 User Manual

Page 25

Advertising
background image

25

80 m

60 m

c

2

c

1

b

1

b

2

a

2

a

1

15 m

20 m

20 m

40 m

40 m

20 m

20 m

30 m

20 m

30 m

30 m

M

Example 3

Ring system

Selection of spray lance: 2 green spray lances each of 33 l/min

2 blue spray lances each of 17 l/min

If the maximum load is distributed evenly and symmetrically the
maximum load on line

b1 - c1 = 33 l/min.

If ∅15 mm pipe is selected 35 m pipes will result

PRESSURE DROP

in a pressure drop of:

6 bar


Maximum load on line

M-a1 + a1-b1 = 50 l/min.

If 90 m ∅22 mm pipe is used the resulting pressure drop will be:

4 bar


Total pressure drop

10 bar

This means that ∅22 mm pipe is to be used from the pumps to outlet points

b1 and b2 and

∅15 mm for the rest.

The examples show different ways of installing the pipe system. What to prefer in each individual
case highly depends on the building where it is to be located and special requirements, if any.
Due regard should be paid to the fact that big pipe dimensions and units are considerably more
expensive, and the financial costs of each solution should therefore always be compared to
one another.

Advertising