TROUBLE SHOOTING

Pilot burner will not stay lit. This could be caused by one (or more) of three problems:

1. Loose connection at thermocouple to the safety control.

2. Worn out thermocouple.

3. Worn out safety control.

To remedy the problem, first check to see if the thermocouple is snug in the safety control.

1. Remove the valve/control cover

3. Light the pilot burner. If the pilot burner stays lit, then the problem was a loose connection at the

thermocouple.

The thermocouple is snug but the pilot burner will not stay lit.

Thermocouples require replacement as often as three months due to the extremely high temperatures in

the combustion chamber of the MBR. To change a themocouple, wait for the unit to cool. Then:

2. Using a 3/8" wrench, insure the thermocouple is

snug in the body of the saftey control. A good rule

is giving a 1/8 turn after finger tightening. DO NOT

OVERTIGHTEN as it will damage the control.

1. Using a 3/8" wrench, remove the thermocouple

from the control.

3. After the thermocouple is installed at the pilot

burner, thread the brass fitting into the safety

body. It should be snug, but not too tight. A

good rule is giving a 1/8 turn after finger tight-

ening. DO NOT OVERTIGHTEN as it will

damage the control. Light pilot.

2. Using a 7/16" wrench, remove and replace

the thermcouple from the pilot burner

bracket. When installing the new

thermocouple, be sure to thread the

adjusting nut up to the top of its travel.