13. Do not locate unit by door or window as air currents adversely affect operation

14.

DO NOT THROW AWAY THESE INSTRUCTIONS. THIS MANUAL MUST REMAIN WITH THE

UNIT FOR FUTURE REFERENCE.

UNIT OPERATION: LIGHTING & SHUT DOWN INSTRUCTIONS

Always follow lighting and shut down instructions below when operating your unit. A five minute complete

shutoff period is required before lighting or relighting it. See diagram below.

1. Check that all gas valves on the unit are turned “OFF” (lever handles in vertical position) before

turning “ON” main gas line. Check for leaks using soapy water or other suitable leak detector.

DO NOT USE OPEN FLAME FOR TESTING.

2. Main burner valve shall be in “OFF” position. Light a match and place it in the lighter rod.

Position the burning match by the pilot burner in the combustion chamber of the smokehouse.

Depress the red button on safely control (see fig 1. below) and light pilot.

3. The pilot should light. Continue to hold the button for one minute or until the pilot stays lit.

4. Set thermostat to desired temperature.

5. Turn main burner valve counterclockwise to “ON” position (fig. 2). Observe that each burner has

ignited with a clear, blue flame that is 3/4” - 1” long.

6. Turn main burner valve to “OFF” position when unit is not in use.

7. Set thermostat to minimum setting.

8. In the event of power failure, blackout or loss of gas, do not attempt to operate this unit.

Set thermostat to

desired temperature

Turn main burner valve

counter-clockwise to

“ON” after thermostat is

set.

Put lit match to pilot

burner, depress &

hold red button

Fig. 1

Fig. 2