Town MasterRange Smokehouses User Manual
Page 6
FOOD SERVICE EQUIPMENT CO., INC. • 72 BEADEL ST • BKLYN • NY 11222
6
OPERATION INSTRUCTIONS
1. Materials such as wood, compressed paper and plant fibers that will ignite and burn, MUST NOT
BE LEFT NEAR THIS UNIT. Local safety codes should be complied with in respect to fire hazard
avoidance.
2. The front of the unit must be kept clear to avoid restriction of air supply for combustion or
ventilation for exhaust.
3. There must be adequate clearance for air openings into the combustion chamber, servicing and
proper operation.
4. This unit should be operated only with water pan in place and filled with water. Drippings,
especially fat, will ignite if the unit is used without water in the water pan. Be sure to drain fat and
refill the water pan if the cooking process allows most of the water to evaporate, such as a slow
cooking brisket.
5. If your unit is supplied with casters, there should be a restraint on the appliance to limit its movement.
If disconnection of the restraint becomes necessary, you must be sure to reconnect the restraint after
the appliance is returned to its originally installed position.
6. This appliance is designed for use with Natural or Propane (bottled) gas only and may be connected
only to the type of gas for which it is equipped as specified on the rating plate secured to the front
of the unit.
7. The installation must conform with local codes, or in the absence of local codes with the National
Fuel Gas Code ANSI-Z223.1:
a) The appliance and its individual shutoff valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2
psig.
b) The appliance must be isolated from the gas supply piping system by closing its individual
manual valve during any pressure testing of the gas supply piping system at test pressures
equal or less than 1/2 psig.
8. The gas supply line must be of adequate size to ensure maximum efficiency of the unit and conform
with the National Fuel Gas Code, ANSI-Z223.1
9. The unit must be installed in an area or room with sufficient fresh air supply to ensure proper
combustion. This unit cannot operate safely without sufficient air supply.
10. Smokehouse installation must have rear clearance of 4” and side clearance of 4” from any
combustible construction. Clearances for non-combustible construction are same as combustible
clearances. Suitable for installation or non-combustible floors.
11. Smokehouse should be used under a hood with adequate ventilation.
12. DO NOT THROW AWAY THESE INSTRUCTIONS. THIS MANUAL MUST REMAIN WITH THE
UNIT FOR FUTURE REFERENCE.