FOOD SERVICE EQUIPMENT CO., INC. • 72 BEADEL ST • BKLYN • NY 11222

6

OPERATION INSTRUCTIONS

1. Materials such as wood, compressed paper and plant fibers that will ignite and burn, MUST NOT

BE LEFT NEAR THIS UNIT. Local safety codes should be complied with in respect to fire hazard

avoidance.

2. The front of the unit must be kept clear to avoid restriction of air supply for combustion or

ventilation for exhaust.

3. There must be adequate clearance for air openings into the combustion chamber, servicing and

proper operation.

4. This unit should be operated only with water pan in place and filled with water. Drippings,

especially fat, will ignite if the unit is used without water in the water pan. Be sure to drain fat and

refill the water pan if the cooking process allows most of the water to evaporate, such as a slow

cooking brisket.

5. If your unit is supplied with casters, there should be a restraint on the appliance to limit its movement.

If disconnection of the restraint becomes necessary, you must be sure to reconnect the restraint after

the appliance is returned to its originally installed position.

6. This appliance is designed for use with Natural or Propane (bottled) gas only and may be connected

only to the type of gas for which it is equipped as specified on the rating plate secured to the front

of the unit.

7. The installation must conform with local codes, or in the absence of local codes with the National

Fuel Gas Code ANSI-Z223.1:

a) The appliance and its individual shutoff valve must be disconnected from the gas supply

piping system during any pressure testing of that system at test pressures in excess of 1/2

psig.

b) The appliance must be isolated from the gas supply piping system by closing its individual

manual valve during any pressure testing of the gas supply piping system at test pressures

equal or less than 1/2 psig.

8. The gas supply line must be of adequate size to ensure maximum efficiency of the unit and conform

with the National Fuel Gas Code, ANSI-Z223.1

9. The unit must be installed in an area or room with sufficient fresh air supply to ensure proper

combustion. This unit cannot operate safely without sufficient air supply.

10. Smokehouse installation must have rear clearance of 4” and side clearance of 4” from any

combustible construction. Clearances for non-combustible construction are same as combustible

clearances. Suitable for installation or non-combustible floors.

11. Smokehouse should be used under a hood with adequate ventilation.

12. DO NOT THROW AWAY THESE INSTRUCTIONS. THIS MANUAL MUST REMAIN WITH THE

UNIT FOR FUTURE REFERENCE.