Installation – AMICA 1143.4TsYDX EN User Manual

Page 10

Advertising
background image

10

2

1

230V 1N~

INSTALLATION

Electrical connection

Warning: This appliance must be earthed.

The appliance must be installed by a com-

petent electrician using a double pole control

unit of 16 ampere minimum capacity with

3mm minimum contact separation at all

poles.

We recommend that the appliance is con-

nected by a qualified electrician who is mem-

ber of the N.C.E.I.C. and who will comply with

the I.E.E. and local regulation.

Access to the main terminal is gained by

opening the terminal block cover at the

rear of the appliance (use a small flat-

bladed screwdriver).

Connection shuld be made with 1,5mm

2

twin and earth cable.

First strip the wires, then push the cab-

lethrough the cable clamp in the terminal

block cover.

Connect the cable to the terminal block

and tighten the cable clamp screw (see

diagram).

Close the terminal box, ensuring that the

cover is engaged on the locking tabs.

Live

(Red or Brown)

Neutral

(Black or Blue)

Earth

(Green/Yellow

or sleeving)

Cable clamp

Advertising