Installation work and repairs should only be performed by a qualified technician in accordance

with all applicable codes and standards. Repairs and service by unqualified persons could

be dangerous and the manufacturer will not be held responsible.

Location

• The kitchen must be dry and well ventilated.
• The kitchen should have a ventilation system including fume exhaust to remove the

gases generated by burning gas and direct them out. That system shall comprise a

ventilation grill or a hood. Please install hods in accordance with the manufacturers’

instructions.

• Fresh air is necessary to ensure gas burning. Minimum gas requirement for the

cooktop is 2 cbm per hour per each 1 kW of the burners’ capacity. The air can be

supplied either directly from the outside by an at least 100 cm

2

duct, or directly from

the adjacent rooms, provided these are equipped with ventilation system routed to

the outside of the building.

• The minimum distance between the burners and the hood exhaust should be 750

mm (see fig. 3).