Valve adjustment

Valve adjustment should be done with the control knob set at Burner ON saving flame po-

sition.

Remove the knob, and adjust the flame with a tiny screwdriver (see fig. 7 below).

fig. 7

Checking the adjusted flame: heat the burner at full open position for 10 minutes. Then turn

the knob into the saving setting. The flame should not extinguish nor move to the nozzle. If

it goes off or moves over to the nozzle, readjust the valves.

Note.

It is up to the used to request converting the appliance to another gas type if so

required by the local conditions at a licensed gas fitter / service.