General Attributes

INPUT ANALOG RANGE:

5 to 10 VDC or 0 to 5 VDC jumper selectable.

POWER SUPPLY REQUIREMENTS:

12Vdc, 100mV Pk-Pk, less than 0.5 watts.
(OPTIONAL, require only for TOT-05).

POWER CONSUMPTION:

10 mA at 12 VDC, less than 0.125 watts.

ACCURACY:

±0.5% of full scale.

TEMPERATURE STABILITY:

±200 ppm/

F

C in the range of 5

F

C to 50

F

C.

DISPLAY:

7 digit, 8-mm figure height.

READING BACKUP:

20 years lithium battery, no external power required.

RESET:

Front panel push button momentary tact switch
(works only when Totalizer is connected to the power).

ALTITUDE:

Up to 10,000 feet.

CONNECTION METHOD:

Telephone modular plug.

d.2 CE Compliance

Any model Totalizer bearing a CE marking on it, is in compliance with
the below stated test standards currently accepted.

EMC Compliance with 89/336/EEC as amended;
Emission Standard: EN 55011:1991, Group 1, Class B
Immunity Standard: EN 55082-1:1992
Environmental (per IEC 664): Installation Level II; Pollution Degree II

Advertising