BERRINGTON SOLID FUEL STOVE INSTALLATION & OPERATING INSTRUCTIONS

GENERAL

When installing, operating and maintaining your
Berrington Stove respect basic standards of fire
safety. Read these instructions carefully before
commencing the installation. Failure to do so may
result in damage to persons and property. Consult
your local Municipal office and your insurance
representative to determine what regulations are in
force. Save these instructions for future reference.

PRE INSTALLATION ASSEMBLY

1.

After removing the stove from its pack, open the
ashpit door and remove the contents.

2.

Fit the front door handle as shown in Fig.1.

3.

Remove the stove from the wooden pallet.

4.

Unscrew the two

1/4

” x

1/2

” round head screws

from the base and fit the front ash tray using the
two screws (see Fig.2).

FLUES

Flues should be vertical wherever possible and
where a bend is necessary, it should not make an
angle of more than 45

o

with the vertical. Horizontal

flue runs should be avoided except in the case of a
back outlet from the appliance, when the length of
the horizontal section should not exceed 150mm.

In order to minimise flue resistance and to make
sweeping easier it is recommended to use 2 x 45

o

bends rather than a 90

o

bend.

The flue termination point must be located to min-
imise any wind effects. Wind effects of suction,
pressure zones and turbulence can be created by
the roof and adjacent objects. Wind effects can also
be created by natural land contours.

To minimise the wind effects, the flue termination
point should be located a minimum of 600mm from
the roof measured vertically and 2300mm measured
horizontally. Where this termination point does not
suffice it may be necessary to extend the flue pipe
so that the termination point is above the apex. (See
Fig.3)

2

The installation must be completed in accordance
with current National and European Standards and
Local Codes. It should be noted that the require-
ments and these publications may be superseded
during the life of this manual.

Fig.1

Fig.2

Fig.3

Fit the primary air control knob to the flexible drive.
(for the boiler model, ensure that the air damper
knob spacer is placed between the knob and the
flexible drive bracket on the back of the boiler). See
Fig.3