FLOOR PROTECTION

It is recommended that this appliance is installed on
a solid, level, non combustible hearth conforming to
current Building Regulations.

Fig.7

The appliance is suitable for continuous operation
on solid mineral fuel and intermittent operation on
wood logs. This appliance has been tested using
seasoned wood logs and manufactured briquetted
smokeless fuel (Ancit) for closed appliances, sized
between 20g and 140g. Other fuels are commer-
cially available. Wood logs up to 400 mm long are
suitable. All fuels should be stored under cover and
kept as dry as possible prior to use.

LOCATION

There are several conditions to be considered in
selecting a location for your Berrington Stove.

a.

Position in the area to be heated- central
locations are usually best.

b.

Allowances for proper clearances to
combustibles.

Note: Sufficient space should be given around

the back and sides of the stove to allow
access to the air control damper.

INSTALLATION CLEARANCES

Maintain at least the following clearances to all
combustible material:
From the front

900 mm

From the Sides

150 mm

From the rear

150 mm

From the flue pipe

600 mm