Axis Communications AXIS 225FD User Manual

Page 6

Advertising
background image

AXIS 225FD - Product Features

6

Power connector block - for connection of a power supply. See Power connections, on page 36.

I/O terminal connector - The I/O terminal connector provides the physical interface to one solid state relay

output, two digital inputs, RS-485/422 and GND. For more information, see Unit Connectors, on page 35.

Network connector - The AXIS 225FD connects to the network via a standard network cable, and automatically

detects the speed of the local network segment (10BaseT/100BaseTX Ethernet). This socket can also be used to

power the AXIS 225FD via PoE (Power over Ethernet). The camera also negotiates the correct power level when

using PoE.

Serial Number - This number is used during installation.
Control Button - This button is used during the installation using the AXIS Internet Dynamic DNS Service (see

the Installation Guide) or to restore the factory default settings, as described in Advanced, on page 33.

LED Indicators
After completion of the startup and self test routines, the multi-colored Network, Status, Heater, and Power LED

indicators flash as follows:

Network

Green

Steady for connection to 100 Mbit/s network. Flashes for network activity.

Amber

Steady for connection to 10 Mbit/s network. Flashes for network activity.

Red

Flashes rapid red, together with the Status indicator, for hardware error.

Unlit

No connection.

Heater

Green

Shows steady green if the connected power supply can deliver the correct voltage for
the heater (See Power, on page 42 of Technical Specifications).

Red

Shows steady red if the connected power supply cannot deliver the correct voltage (i.e.,
the voltage is either too high or too low).

Status

Green

Shows steady green for normal operation. Can be configured to flash green at intervals
whenever the camera is accessed. See the online help for more information.

Amber

Shows steady amber during reset to factory default or when restoring settings.

Red

Slow flash for failed upgrade (see Emergency Recovery Procedure, on page 38).
Rapid flash, together with the Network indicator, for hardware error.

Unlit

When configured for “no flash” on camera access.

Power

Green

Normal operation.

Amber

Flashes green/amber during firmware upgrade.

Advertising