Garmin 16-HVS GPS Receiver

Warm Start

One satellite in use, time from GPS Real Time Clock (not GPS), no position:

$GPGGA,183806.0,,,,,0,01,,,,,,,*7D

Valid GPS Fix

Three satellites acquired, time and position valid:

$GPGGA,005322.0,4147.603,N,11150.978,W,1,03,11.9,00016,M,-016,M,,*6E

If the almanac and ephemeris data are not stored in the non-volatile data, GPS

acquisition time is less than 5 minutes. If only the ephemeris data are

unknown, acquisition time is less than 45 seconds. If all data are known (warm

start), GPS acquisition time is less than 15 seconds.

4. CRBasic Programming

CRBasic is used to write programs for the CR1000, CR3000, CR800, and

CR850 dataloggers. These dataloggers use several instructions to read GPS

output, which is asynchronous serial data. As shipped from Campbell

Scientific, the GPS receiver will output data once a second, 1200 baud, 8 data

bits, no parity, and 1 stop bit. Only the GPGGA string is output. See Section 3

for details on the GPGGA string. See Appendix D for specifics on changing

the GPS receiver setups, including using higher baud rates, which the CR1000,

CR3000, CR800, and CR850 support.

4.1 Read GPS Data

4.1.1 SerialOpen

SerialOpen is used to open the appropriate serial port, specify the baud rate,

data format, etc. Any of the six serial ports may be used, but option codes 3, 4

and 5 are not used in this application. Data format is zero, TX delay is zero,

buffer size should be about 2000, which is large enough to prevent the GPGGA

string from overrunning the buffer before data is read by the SerialIn

instruction. If memory is limited, the buffer size can be smaller.

Example: SerialOpen (com1,1200,0,0,2000)

4.1.2 SerialIn

The SerialIn instruction removes data from the buffer declared in the

SerialOpen instruction and places the data in a variable of type string. Use a

timeout of 20, a termination character of 13, and maximum number of

characters of 100, or 1 less than the size of the destination variable. Declare a

string variable of size 101 before using SerialIn.
Example: Public GPSdata as string * 101
Example: SerialIn (GPSData,com1,20,13,100)

4.1.3 SerialFlush

The SerialFlush instruction is used to clear all data from the buffer associated

with the serial port.

4.1.4 SerialClose

The SerialClose instruction is used to close the serial port. Once closed, the

SerialOpen command must be used before more data can be read.