1 enclosure installation, Enclosure installation, 7. enclosure spacing above pole – Campbell Scientific ET107 Evapotranspiration Monitoring Station User Manual
Page 27
ET107 Weather Station
2.3.1 Enclosure Installation
1. Mount the ET enclosure on the ET Tower as shown in FIGURE 2-7.
a. Remove the front lid. Remove the connector cover from the back of
the ET enclosure by loosening the Phillips screw at the bottom of the
cover.
b. Loosen the mounting bracket bolts on the back of the enclosure wide
enough to slide over the pole. Slide the enclosure over the pole.
Position the enclosure so it faces east for northern latitudes or west
for southern latitudes. The top of the enclosure should be 2 to 2.5 cm
(3/4 to 1 in) above the top of the pole (see FIGURE 2-7).
FIGURE 2-7. Enclosure spacing above pole
Power Cable
(if using AC
transformer)
Ground
Wire
COM Cable
(if using phone or
short-haul modem)
2 – 2.5 cm
17