5. Move the jumper so that it is placed over the center and right pins (see
FIGURE 2-23. Jumper set for CS616
6. Replace electronics cover.
7. Tighten screws.
8. Reattach 10588 ribbon cable to the CS I/O port.
9. Replace enclosure cover.
2.4.9.2 Site Installation
The CS616-LC water content sensor does NOT have an armored outer jacket.
The jacket is waterproof but NOT cut proof. The recommended method is to
bury conduit from the weather station to the soil water content measurement
site and route the sensor cable through the conduit. Bury the end of the sensor
so its rod ends are in contact with the soil surface to be measured. See manual
for complete instructions.
This sensor plugs into the enclosure connector marked “TEMP CS616”.
The cable used with the CS616-LC water content reflectometer
sensor is waterproof but not armored. Route cable through
conduit if rocky soils or rodents are present.
NOTE
New Jumper Position