ET107 Weather Station

5. Move the jumper so that it is placed over the center and right pins (see

FIGURE 2-23).

FIGURE 2-23. Jumper set for CS616

6. Replace electronics cover.
7. Tighten screws.
8. Reattach 10588 ribbon cable to the CS I/O port.
9. Replace enclosure cover.

2.4.9.2 Site Installation

The CS616-LC water content sensor does NOT have an armored outer jacket.

The jacket is waterproof but NOT cut proof. The recommended method is to

bury conduit from the weather station to the soil water content measurement

site and route the sensor cable through the conduit. Bury the end of the sensor

so its rod ends are in contact with the soil surface to be measured. See manual

for complete instructions.

This sensor plugs into the enclosure connector marked “TEMP CS616”.

The cable used with the CS616-LC water content reflectometer

sensor is waterproof but not armored. Route cable through

conduit if rocky soils or rodents are present.

NOTE

New Jumper Position