• Screw (pn 505) and grommet (pn 6044) to secure the polyphaser protector

to the backplate of an enclosure

• 1.5 ft, 10 AWG ground wire (insert one end of the wire between the #505

screw and the polyphaser, then secure the other end to a ground lug)

5. LoggerNet Software Setup

The Device Map is configured from the “Setup” button on the LoggerNet or
PC400 toolbar. Configure the Device Map as described below (see Figure
5.1-1).

1. Select Add Root | COM Port.

2. Add a PakBusPort, set the Maximum Baud Rate to 115200, set the beacon

interval to 60 seconds if the Master radio will be at the PC.

3. Add datalogger, set the PakBus address to match that of the datalogger.

4. Apply Settings.

FIGURE 5.1-1. LoggerNet Setup Screen for an RF450 Multi-Point Network