background image

Appendix A. Installation Scenarios

Master

RF450

Slave 12

Slave 11

PC Running

LoggerNet

/PC400

Repeater

1

Slave/

Repeater

Slave 22

Slave 21

FIGURE A.3-1. Schematic of PC-to-RF Network with Parallel

Repeaters (using the SubNet ID)

TABLE A.3-1. RF450 Settings for Example 3


Master


Repeater


Slave/Repeater

Slave
11, 12 etc.

Slave
21, 22 etc.

Hardware(d)

PC running
LoggerNet, RF450

RF450 CR1000,

RF450

CR1000,
RF450

CR1000,
RF450

Baud Rate

115.2K

115.2K

115.2K

115.2K

115.2K

Radio Operation
Mode

Multi-Point Master

Multi-Point
Repeater

Multi-Point
Slave/Repeater

Multi-Point
Slave

Multi-Point
Slave

Repeaters Used

Yes; check box

Yes; check
box

Yes; check box

Yes; check
box

Yes; check
box

Network ID (a)

1726

1726

1726

1726

1726

Frequency Key
(a)

1 1

1 1

1

Receive SubNet
ID

NA 0

0

1

2

Transmit SubNet
ID

15 (default)

1

2

0

0

Radio ID

4094(b)

2

3 (c)

11, 12 etc.
(c)

21, 22, etc
(c)

Notes:
(a) your Network ID and Frequency Key may be different
(b) to match LoggerNet's PakBus Address
(c) to match CR1000's PakBus Address
(d) not inclusive; other typical hardware items may include power supply, antenna, enclosure, etc.
NA = not applicable

A-6