Appendix A. Installation Scenarios

FIGURE A.1-2. DevConfig Screen Showing Master Radio Settings for Example 1

TABLE A.1-1. RF450 Settings for Example 1

Master Slave(s)

Hardware

RF450 connected to PC running LoggerNet RF450 connected to CR1000's CS I/O

port

Keep all factory default settings except:
Radio Operation Mode

Multi-Point Master

Multi-Point Slave

Network ID

1726 (yours may be different)

1726 (yours may be different)

Frequency Key

1 (yours may be different)

1 (yours may be different)

Radio ID

4094 (to match LoggerNet's PakBus
Address)

2 (to match CR1000's PakBus Address)
(a)

(a) All Slave Radios in the network will have these same settings except for the Radio ID. The Radio ID should
match the PakBus Address of the datalogger it is connected to.

The Device Map in LoggerNet's Setup screen will look something like this:

A-2