Campbell Scientific TD Operating System Addendum for CR510, CR10X, and CR23X User Manual

Page 34

Advertising
background image

TD ADDENDUM—SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES

AD-8-4

FIGURE 8.3-1. AM416 Wiring Diagram For Thermocouple and Soil Moisture Block Measurements

EXAMPLE PROGRAM MULTIPLEXING
THERMOCOUPLES AND SOIL MOISTURE
BLOCK

*

1

Table 1 Programs

01:

600

Sec. Execution Interval

01:

P11

Temp 107 Probe

01:

1

Rep

02:

4

IN Chan

03:

1

Excite all reps w/EXchan 1

04:

1

Loc [:REF_TEMP ]

05:

1

Mult

06:

0

Offset

02:

P86

Do

01:

41

Set high Port 1

03:

P87

Beginning of Loop

01:

0

Delay

02:

16

Loop Count

04:

P86

Do

01:

72

Pulse Port 2

05:

P14

Thermocouple Temp (DIFF)

01:

1

Rep

02:

21

2.5 mV 60 Hz rejection
Range

03:

1

IN Chan

04:

1

Type T (Copper-Constantan)

05:

1

Ref Temp Loc REF_TEMP

06:

2--

Loc [:TC_TEMP_1]

07:

1

Mult

08:

0

Offset

06:

P5

AC Half Bridge

01:

1

Rep

02:

14

250 mV fast Range

03:

3

IN Chan

04:

1

Excite all reps w/EXchan 1

05:

250

mV Excitation

06:

18--

Loc [:SOIL_M_1 ]

07:

1

Mult

08:

0

Offset

07:

P95

End

08:

P86

Do

01:

51

Set low Port 1

09:

P59

BR Transform Rf[X/(1-X)]

01:

16

Reps

02:

18

Loc [:SOIL_M_1 ]

03:

.1

Multiplier (Rf)

10:

P84

Data Table

01:

0

Seconds into interval

02: 3600

Seconds interval

03:

0

Records (0=auto; -=redirect)

11:

P71

Average

01:

33

Reps

02:

1

Loc REF_TEMP

12:

P

End Table 1

CR10X