Campbell Scientific TD Operating System Addendum for CR510, CR10X, and CR23X User Manual

Page 39

Advertising
background image

TD ADDENDUM—SECTION 8. PROCESSING AND PROGRAM CONTROL EXAMPLES

AD-8-9

Loop 6, Output every 10 minutes until stopped
by user

17:

P87

Beginning of Loop

01:

60

Delay

02:

0

Loop Count

18:

P86

Do

01:

1

Call Subroutine 1

19:

P91

If Flag/Port

01:

21

Do if flag 1 is low

02:

31

Exit Loop if true

20:

P95

End

21:

P

End Table 1

*

3

Table 3 Subroutines

01:

P85

Beginning of Subroutine

01:

1

Subroutine Number

02:

P6

Full Bridge

01:

1

Rep

02:

22

7.5 mV 60 Hz rejection Range

03:

1

IN Chan

04:

1

Excite all reps w/EXchan 1

05: 1500

mV Excitation

06:

1

Loc [:LEVEL_FT ]

07:

.46199 Mult

08:

102

Offset

03:

P84

Data Table

01:

0

Seconds into interval

02:

0

Every time

03:

0

Records (0=auto; -=redirect)

04:

P70

Sample

01:

1

Reps

02:

1

Loc LEVEL_FT

05:

P95

End

06:

P

End Table 3

Advertising