Data mapping, 1 report field mapping – Campbell Scientific VisualWeather Software User Manual

Page 44

Advertising
background image

VisualWeather

Software

To remove a station from the network, select it and click the Remove Station
button. The station will become a past weather station. Reports may still be
generated for the station with historical data, but no new data can be collected
from the station. A station may be removed from the network completely from
the Network | Remove Station menu item.

The Remove action cannot be undone.

NOTE

To edit the configuration for a weather station, select it and click the Edit
Station
button. The EZSetup Wizard as described in section 5.1 is opened.
To quickly move to a specific section of the Wizard, select it from the Progress
panel on the left size of the Wizard.

11. Data Mapping

Data mapping is required to associate measurements and final storage data in a
custom weather station with the values required for report generation and
monitoring of current conditions and status.

11.1 Report Field Mapping

Data mapping required for report generation is done from the Report Field
Mapping screen of the EZSetup Wizard. (Report Field Mapping is the second
screen under the Data Files/Mapping section of the EZSetup Wizard.)

Each required Report Parameter needs to be associated with a value, or Data
Field
, in the datalogger.

To map a value, first select the data table or array ID that contains the value
you want to associate from the Tables list. When a table or array is selected,
the values in that table or array are displayed in the Fields list. Click the Data
Field
cell for which you want to map a value, and then highlight a data value
from the Fields list and click the right-pointing arrow (or double-click the
value). The name of the field will be displayed in the Data Field when it has
been mapped. To clear an association, right click and select Clear. The Field
Units
field should specify the units of the data value from the datalogger. This
will be converted as needed for purposes of the reports. If the default unit is
incorrect, click within the field to enable a list box from which to select an
appropriate unit.

Report parameters required for report generation are shown below. Unless
noted otherwise, all listed parameters are required for the specified report. All
parameters used for any one report must have the same interval.

Battery Voltage

• Battery Voltage Min (required)
• Battery Voltage Max (optional)

Enclosure Relative Humidity

• Enclosure RH Max

34