Campbell Scientific VisualWeather Software User Manual

Page 61

Advertising
background image

Appendix A. Evapotranspiration, Vapor Pressure Deficit, and Crop Water Needs

where the atmospheric pressure is obtained from the following equation:

P = 101.3

293- 0.0065Z

293

5.26


⎣⎢


⎦⎥

(18)

where, Z = Elevation in meters. In the above calculation the temperature
is assumed to be 20°C; hence,

T (Kelvin) = T (°C) + 273 =293. Note that by taking the value of
temperature to be 20 °C at all altitudes the temperature dependence of

γ

has been ignored.

At sea level Z= 0; therefore, P = 101.3 kPa. At a higher altitude the
pressure P drops below this value, since the air is less dense. As the
altitude increases, P decreases and so does

γ.

VisualWeather computes the atmospheric pressure, P, based on the user-
entered elevation.

Note that the latent heat of vaporization of water,

λ is also a function of

temperature. However, its variation with temperature is small enough to
be neglected. For the FAO 56 PM equation the value of

λ is assumed to

be constant,

λ = 2.45 MJ/kg.

5. Calculation of e°(T

hr

) (saturation vapor pressure at air temperature

T

hr

).

The saturation vapor pressure is related to air temperature, T

e°(T

hr

) = 0.6108 e

(17.27T) / (T + 237.3)

(19)

Note that the right-hand side of this equation forms a part of the
numerator in equation (3) above.

6. Calculation of e

a

(average hourly actual vapor pressure).

e

a

= e°(T

hr

)*RH

hr

/100 (20)

RH

hr

is the average hourly relative humidity (%)

Finally these individual results are combined to calculate hourly values of
ET

o

by using equation (2).

Denominator

=

Δ + γ (1 + 0.34 u

2

)

First term = 0.408

Δ (Rn-G) / (Δ + γ (1 + 0.34 u

2

))

Second term =

γ (37/(T

hr

+ 273)) u

2

(e°(T

hr

)-e

a

)) / (

Δ + γ (1 + 0.34 u

2

))

ET

o

(mm/hour) = First term + Second term

A-7

Advertising