Setting the dip switch, Reassembly – AMX ViewStat User Manual

Page 15

Advertising
background image

ViewStat Installation and Wiring

9

ViewStat Communicating Thermostat

Setting the DIP Switch

Set the DIP switch located on the thermostat circuit board (FIG. 4) according to the application needs (see the
DIP Switch Settings table below for details).

The following table shows what each switch corresponds to depending on position. Switch one should be set in
the “OFF Servant” position unless you plan to broadcast readings from remote temperature sensors to other
thermostats in the system when there is no control system in place.

Reassembly

No tools required – line up pins on circuit board with the corresponding terminal blocks. Use your hands to
push the front panel securely to the mounted base.

FIG. 4

Setting the DIP Switch

DIP Switch Settings

Application

Switch

#1

Switch

#2

Switch

#3

Switch

#4

Single Stage Furnace & AC

Servant

Fossil

Single

H/C

Two Stage Furnace & Two Stage AC

Servant

Fossil

Multi

H/C

Roof Top Unit (Two Stage Heat & Two Stage Cool) Servant

Fossil

Multi

H/C

Boiler with AC (Two Transformers)

Servant

Fossil

Single

H/C

Single Stage Heat Pump

Servant

Electric

Single

HT. Pump

Two Multi-stage Heat Pump

Servant

Electric

Multi

HT. Pump

First Stage Radiant Floor Heat,
Second Stage Furnace One Stage of Cooling

Servant

Fossil

Multi

H/C

OF

F

ON

SER

VAN

T

MAST

ER

EL

EC

TR

IC

FO

SS

IL

SIN

G

LE

MU

LT

I

HT

.P

UM

P

H/

C