Connecting the viewstat to the hvac system, Caution, Connecting the viewstat to the hvac system 1 – AMX ViewStat User Manual

Page 27: Make sure the hvac system power is off

Advertising
background image

ViewStat Installation and Wiring

21

ViewStat Communicating Thermostat

Connecting the ViewStat to the HVAC System

1.

Make sure the HVAC system power is off.

2.

The following figures (FIG. 14, FIG. 15) show wiring diagrams for several different HVAC equipment
types. Use these diagrams as a reference only. Use color coding where possible.

a.

FIG. 14 shows a typical heat/cool wiring schematic:

Communication and Equipment Terminal Wiring Definitions (Cont.)

Equipment Terminal (Cont.)

DEH/Y1

1st stage Cooling (non-heat pump)
-or-
1st stage Compressor (heat pump)
-or-
Dehumidification (with humidity control sensor)

W2

2nd stage Heat (non-heat pump)
-or-
2nd stage Emergency Heat (heat pump)

Y2

2nd stage Cooling (non-heat pump)
-or-
2nd stage Compressor (heat pump)

A qualified HVAC technician should perform these steps step to ensure proper
termination.

FIG. 14

Typical heat/cool wiring schematic

RC

RH

Y1

W1

G

O

W2

C

RSC

RSA

RSB

RSR

R

REF

Y2

B-

B+

A+

A-

B

FAN

RELAY

2ND

STAGE

HEAT

1ST

STAGE

HEAT

R

MULTI-STAGE FURNACE

C

G

W1

Y1

W2

Y2

1ST STAGE

COOL

2ND STAGE

COOL

L1

L2

120

VAC

24

VAC

1ST

STG

COOL

2ND
STG

COOL

MULTI-STAGE A/C

Y1

C

Y2

CAUTION!

ENSURE HVAC SYSTEM POWER

IS OFF BEFORE WIRING

USE 18-20 GA. THERMOSTAT CABLE. NUMBER OF CONDUCTORS
REQUIRED DEPENDS ON THE HVAC SYSTEM BEING CONTROLLED

REFER TO THE THERMOSTAT INSTALLATION SHEET FOR
INTERNAL SCHEMATIC, THERMOSTAT CHECK-OUT
PROCEDURES AND OTHER HVAC WIRING DETAILS

(from MiniVerter)

Black

(common)

Red
(power)

Advertising