Numeric keys 1-6 used for instant
source input selection and navigation

ZONE key used to select a single Wallplate

GROUP key use to select a group of Wallplates

MENU key used to access AVX-562 setup menu

SCAN keys used to browse

AVAtrix inputs or navigation

DIM/SCROLL (up/down) used to dim AVX-
562 panel display and for navigation

ALL key used to select all Wallplates

SOURCE key used to select source
input to Wallplates (Double click for
main output control in Pro Mode)

LOCK key used in conjunction with VIEW-
LOCK, IR-LOCK, and UNLOCK keys

ENTER key used to make menu selections

DISPLAY key used to switch between Resi-
dential and Professional panel display mode

800-322-8346

www.audioauthority.com

MENU

LOCK

ZONE

SOURCE

GROUP

ALL

A

D

G

J

B

E

H

K

C

F

I

L

SCAN

DIM / SCROLL

ENTER

DISPLAY

Model 1105BK IR Remote

UNLOCK key used to cancel all temporary
restrictions

VIEW-LOCK key used for private viewing restriction

IR-LOCK key used for source control restriction

Use the 1105BK remote to operate the AVAtrix from the
head end or from a properly equipped Cat 5 receiver
zone. Setup functions are only available at the head
end. The 1105 IR command set can be used in a 3rd
party universal remote control system; download the
ccf file from www.audioauthority.com/page/software.

Model 1105BK Remote Control

AVAtrix Front Panel Controls

(From Professional Screen)

Changing the source on the
local (MAIN) output

Touch soft key until MAIN is highlighted; touch the desired source input selection key or
turn the knob.

Changing the source on a
ZONE (Cat 5 receiver)

Turn the knob to navigate, press the knob to change directions; when the desired zone
is highlighted, touch the desired source input selection key.

Changing the source for a
group of zones

Touch soft key until GRP is highlighted; turn the knob to select the desired group; touch
a source input selection key to assign a source.

Changing the source for all
zones

Touch soft key until ALL is highlighted; touch the desired source input selection key to
assign a source. (Press the knob to UNDO.)

Remote Zone Operation: Key Sequence Examples

The key sequences for several operations using the 1105BK IR remote control from the Cat 5 wallplate/
receiver zone are shown below. The zone must be equipped with a compatible IR receiver.

View-lock and IR-lock timeout after 300 minutes. These commands can be temporarily suspended using the
Source and Control Restrictions Diagnostic Mode.

Changing the source on the
zone output

Press the desired source number key.

Activate VIEW LOCK
(private viewing)

Press LOCK, then press VIEW LOCK. No other zones can select the source selected
at this zone, and zones viewing this source are locked out. (Expires after 300 minutes.)

Activate IR LOCK

Press LOCK, then press IR LOCK. No other zones can change settings (channels, etc)
through the AVAtrix IR pathway. (Expires after 300 minutes.)

Clear all LOCK commands

Press LOCK, then UNLOCK.