Query commands (extended) – Audio Authority High Definition Cat 5 Matrix AVX-562 User Manual

Page 27

Advertising
background image

26 Audio Authority AVAtrix User Manual

Audio Authority AVAtrix User Manual 27

Query Commands (Extended)

Query:

Response:

Description:

[?,C,Rx,On]

(Rx,On,Im)

Query unit connection

[?,C,M]

(M,Im)

Query main connection

[?,C,X]

see below

Query all connections

[?,{L,U},P]

(P,{L,U})

Query status of panel lockout

[?,{L,U},I]

(I,{L,U})

Query status of internal I/R lockout

[?,{L,U},A]

(A,{L,U})

Query status of AutoSelect lockout

[?,{+,-},B]

(B,{+,-})

Query status of Display blanking

[?,{+,-},P]

(P,{+,-})

Query status of Display Screen

[?,{+,-},A]

(A,{+,-})

Query status of AutoSelect function

Any command not in the Exended Command Set which begins with a left bracket [ and ends with a right
bracket ] is an invalid command and the AVAtrix responds with the string (ERROR).

Response to [?,C,X] :
(RA,O1,Im)(RA,O2,Im)(RA,O3,Im)(RA,O4,Im)(RA,O5,Im)(RA,O6,Im)
(RB,O1,Im)(RB,O2,Im)(RB,O3,Im)(RB,O4,Im)(RB,O5,Im)(RB,O6,Im)
… through all devices …
(M,Im)

Power Up, Extended Commands and Their Effect on Echo Function

On power up, the AVAtrix sends the string (RESET). The AVAtrix also echoes any data received on the RS-
232 port. If any valid normal command is received (beginning and ending with brackets [ and ] ), the AVAtrix
ceases echoing characters to prevent these echoed characters from corrupting responses. The echo function
remains off until the AVAtrix is reset, either by interrupting power or by double-pressing the front panel button.