Extended command set, Command definitions (extended), General commands (extended) – Audio Authority High Definition Cat 5 Matrix AVX-562 User Manual

Page 26

Advertising
background image

26 Audio Authority AVAtrix User Manual

Audio Authority AVAtrix User Manual 27

Extended Command Set

All valid commands receive a response, and all changes in the AVAtrix system are reported. In the “Com-
mand” column on the next page, actual commands are shown in upper case, and variables are represented
by lower case bold characters (commands are not case-sensitive).

Command Definitions (Extended)

Command: String received by the AVAtrix from the controlling hardware. Commands are not case sensitive
and should be 8-bit with No parity. The only characters recognized are: letters (a-z and A-Z), numbers (0-9),
brackets ([ and ]), signs (+ and -), and the question mark (?) . All other characters, including spaces and com-
mas, are optional and may be either included for clarity or omitted entirely.

Response: String transmitted by the AVAtrix to the controlling hardware. Responses are 8-bit with no parity.
Responses are transmitted as noted below, and always have a C/R L/F sequence (0x0d, 0x0a) after each
line.

Query: A special command that requests the current status of one or more connections or settings, but does
not change any operation within the AVAtrix. A query must always contain the ? question mark character.

Parameters: Values contained within commands and responses which identify groups, sources, zones, and
router devices.
j: group in range {1-6}
m: source in range {1-6}
n: zone in range {1-6}
x: A/V router device in range {A-L}

In this document, braces { and } are used to signify ONE of the enclosed characters. For example, {L,U}
would mean either of the two characters L or U .

General Commands (Extended)

Command:

Response:

Description:

[C,M,Im]

(M,Im)

Connect main output to source m

[C,Rx,On,Im]

(Rx,On,Im)

Connect zone n of A/V router x to source m

[C,X,Im]

(X,Im)

Connect all zones on all A/V routers to source m

[C,Gj,Im]

(Gj,Im)

Connect all outputs in group j to source m

[L,P]

(P,L)

Lock out front panel controls

[U,P]

(P,U)

Unlock front panel controls

[L,I]

(I,L)

Lock out internal I/R receiver

[U,I]

(I,U)

Unlock internal I/R receiver

[+,B]

(B,+)

Turn on display blanking after 45 seconds of inactivity

[-,B]

(B,-)

Turn off display blanking

[+,P]

(P,+)

Select Professional Screen

[-,P]

(P,-)

Select Residential Screen