Nilfisk-ALTO CLE8.0 User Manual

Page 13

Advertising
background image

4.3 Peak Limiter Section

5. INSTALLATION AND CONNECTION

5.1 Mains Connection

5.2 Audio connection

Chart.7: SGC characteristic of the limiter section

12

Chart.6: The effect of a compressor can be expressed as the amount
of gain reduction that is taking place for any given input

Peak Limiting

6ms

15ms

Level

Program Limiting

Input

Release

Output

approx. 1 s

Threshold

t/ms

30

20

10

How fast is the compressor to react to a signal which is above the threshold point? This is determined by the attack
time. A longer attack time is advisable to process low frequencies while shorter attack time is preferable for high
frequencies. In this way you will avoid undesired dynamic distortion. But what about if you are mixing a program
with a wide range of frequencies? In this case you should choose a setting that would benefit the low frequency
better.

Well, life is not that easy for conventional compressor/limiters. Ok you handle an audio signal made by a wide
range of frequencies and you have chosen a longer attack time. But, if are using your CLE 8.0 as a limiter the fast
high frequencies will pass through untouched because the attack time is too slow and such transients could cause
distortion when the unit is connected to broadcast devices or taper recorders. The solution in CLE 8.0 is represe-
nted by our Smart Gain Control (SGC) limiter circuit. The curve in bold is the output signal and the dashed curve
above it is the input signal. The area in between the two is the amount of gain reduction.

The unit will activate the limiter when the signal exceeds the threshold for more than 15 microseconds. Then 1
second after that the signal is below threshold again, reduction goes back to 0dB and in this case input and output
signals are again identical.

The CLE 8.0 Compressor/Limiter/Gate is equipped with balanced XLR connectors as well as 1/4" phone jack and
can be connected with other units in different ways to support a vast range of applications without experiencing a
signal loss.

You must check the power supply Voltage available in your Country before connecting the unit to the Mains.

Advertising