LOCALIZED INSTALLATION AND OPERATION

In this configuration the dehumidifier will pull air from an area in the home. The air passes through the dehumidifier, where
moisture is removed, and then is returned to the area. This installation is used when the HVAC unit conditions an area other than
where dehumidification is needed. An unconditioned basement or crawl space application is ideal for this installation.

None

REQUIRED COMPONENTS

OPTIONAL COMPONENTS

Duct Work

24 VAC Transformer (10 VA minimum) for Ventilation Damper

Thermostat Wire

6506 Ventilation Damper

8052 Outdoor Temperature Sensor

Grilles

Normally Closed Condensate Overflow Safety Switch

RETURN
AIRFLOW

OPTIONAL

OUTDOOR AIR INTAKE

AIR CLEANER

COOLING COIL

TO GRILLE OR

TO OPEN SPACE

HVAC UNIT

OPTIONAL N.C.
VENT CONTROL
DAMPER
(SEE PAGES 10-11)

1700

SUPPLY

AIRFLOW

FROM GRILLE

OR OPEN SPACE

FIGURE 6 – DUCTING