WHOLE HOUSE / LOCALIZED CONVERTIBLE INSTALLATION AND OPERATION

In this configuration the dehumidifier will automatically switch between whole-house dehumidification when the HVAC
equipment is on, and localized dehumidification when the equipment is off. This installation is used to dehumidify a whole house
and a separate unconditioned space like an unfinished basement, or an area where circulation from that location throughout the
entire house is undesirable.

2 – 6508 Normally Closed Power Open Damper

2 – 6608 Normally Open Power Closed Damper

Duct Work

24 VAC Transformer (40 VA minimum)

Thermostat Wire

REQUIRED COMPONENTS

OPTIONAL COMPONENTS

6506 Ventilation Damper

24 VAC Transformer (10 VA minimum) for Ventilation Damper

8052 Outdoor Temperature Sensor

Normally Closed Condensate Overflow Safety Switch

OPTIONAL

OUTDOOR AIR INTAKE

6“ MIN

RETURN
AIRFLOW

6“ MIN

AIR CLEANER

COOLING COIL

OPTIONAL
N.C. DAMPER

HVAC UNIT

1700

N.O. DAMPER

3‘ MIN

SUPPLY

AIRFLOW

N.O. DAMPER

N.C. DAMPER

N.C. DAMPER

RETURN FROM

UNCONDITIONED

SPACE

SUPPLY TO

UNCONDITIONED

SPACE

FIGURE 9 – DUCTING