Axlink data and power connections – AMX Mio Modero Device Family User Manual

Page 13

Advertising
background image

Installation

9

Mio Modero Device Family

AxLink Data and Power Connections

Connect the control system's AxLink connector to the AxLink connector on the rear panel of the Mio Modero
for data and 12 VDC power as shown in FIG. 6.

Using AxLink For Data With an Auxiliary Power Supply

Connect the controller’s AxLink connector to the AxLink connector on the rear panel of the Mio Modero
device, as shown in FIG. 7.

Use an auxiliary 12 VDC power supply when the distance between the controller and server exceeds the limits
described in Wiring Guidelines table.

Connect only the GND (-) wire on the AxLink connector when using an auxiliary 12 VDC power supply.

FIG. 6

AxLink straight-thru wiring

FIG. 7

AxLink and 12 VDC power supply wiring diagram

PWR +

AXP

AXM

GND -

PWR +
AXP

AXM

GND -

Mio Modero

Control System

PWR +

AXP

AXM

GND -

PWR +
AXP

AXM

GND -

Mio Modero

Control System

12VDC Power Supply

PWR +
GND -

If you are not using power from AxLink, disconnect the wiring from the controller
before wiring the Mio Modero device. Make sure the auxiliary power supply’s PWR
(+) is not connected to the controller’s AxLink connector.

Advertising