Mounting procedures, Wallbox mounting – AMX Mio Modero Device Family User Manual

Page 14

Advertising
background image

Installation

10

Mio Modero Device Family

Mounting Procedures

FIG. 8 shows the wallbox mounting dimensions for the single and double style Mio Modero. AMX
recommends mounting the Mio Modero in a standard one-gang wallbox, a conduit box per NEC specs section
370, with a minimum internal clearance of 2-5/8" x 1-3/4" x 1-5/8" (HWD), but it is possible to mount the Mio
Modero to a podium without a wallbox.

Wallbox Mounting

1.

Use the cutout dimension for the wallbox to cutout the install surface for the Mio Modero.

2.

Confirm that the terminal end of the AxLink cable is disconnected, and not receiving power.

3.

If the faceplate is connected to the mounting frame, place a flathead screwdriver in the notch at the
bottom right of the Mio Modero, and pry the faceplate from the mounting frame.

4.

Connect the AxLink power supply. The connector passes through the center of the mounting frame and
connects to the board. The connection is illustrated in FIG. 2.

5.

Place the mounting frame on the wallbox; align the screw holes with the mounting holes and fasten the
mounting frame to the wallbox using the screws supplied.

FIG. 8

Mio Modero Single Style mounting dimensions

FIG. 9

Mio Modero Double Style mounting dimensions

2.250

[57.2 MM]

[83.4 MM]

3.282

[50.8 MM]

2.000

2.250

[57.2 MM]

[83.4 MM]

3.282

[50.8 MM]

2.000

Advertising