Wiring and installation, Setting the axlink device number, Wiring guidelines – AMX Mio Modero Device Family User Manual

Page 18

Advertising
background image

Mio Modero IR

14

Mio Modero Device Family

Wiring and Installation

Set the receive AxLink device number before installing the Mio Modero IR. FIG. 12 illustrates the location of
key components on the Mio Modero IR circuit board.

Setting the AxLink Device Number

1.

If connected, disconnect the power supply.

2.

Locate the 8-position Device DIP switch (FIG. 12).

3.

Set the DIP switch according to the DIP switch values shown below.

The device number is set by the total value of DIP switch positions that are ON (up).

As an example, the DIP switch in FIG. 13 defines device number 129 (1+128=129).

If you later change the device number, remove and reconnect the AxLink power connector to enter the new
device number into memory.

Wiring Guidelines

The Mio Modero IR requires 12 VDC power to operate properly. The power is supplied by the AMX system's
AxLink cable. The maximum wiring distance between the Central Controller and the receiver is determined by
power consumption, supplied voltage, and the wire gauge used for the cable.

The following table lists wire sizes and the maximum lengths allowable between the receiver and the Central
Controller. The maximum wiring lengths are based on a minimum of 13.5 volts available at the Central
Controller's power supply.

FIG. 12

Location of key components on the Mio Modero IR circuit board

Switch 1 2 3 4 5

6

7

8

Value

1 2 4 8 16 32 64 128

FIG. 13

Example Device DIP Switch set to 129

Wiring Specifications @ 35 mA

Maximum Wiring Length
Wire Size

Distance

18 AWG

3000 feet (914.40 m)

20 AWG

2121.64 feet (646.68 m)

22 AWG

1,322.75 feet (403.17 m)

24 AWG

833.80 feet (254.14 m)

AxLink

3.5 mini Phoenix

connector

Notch to pry

faceplate free

(Rear Single)

8 position mini

DIP switch

Screw

holes

PWR+